tantgangbest001 发表于 2010-10-30 20:26

帮忙看下错误提示

*** WARNING ***                         CP =       7.266   TIME= 14:19:07
Element 4 has a diameter to thickness ratio less than 20.The assumed
thin-walled pipe theory may not be valid.                              
Check real constant table 1.                                          

*** ERROR ***                           CP =       7.266   TIME= 14:19:07
Element 4 has a subtended angle that is too large.                     
Check node locations and third constant in real constant table 1.      

tantgangbest001 发表于 2010-10-30 20:27

命令流如下:
/PREP7   
ET,1,PIPE60   
R,1,57,3.5,150,   
MP,EX,1,,2e11   
MP,PRXY,1,,0.3   
MP,DENS,1,,7850
ET,2,PIPE16   
R,2,57,3.5,0,0,0,1142,   
N,1,,,,,,,
N,2,,200,,,,,   
TYPE,   2   
MAT,       1
REAL,       2   
ESYS,       0   
SECNUM,
TSHAP,LINE   
FLST,2,2,1
FITEM,2,1   
FITEM,2,2   
NWPAVE,       2
N,3,,112,,,,,   
TYPE,   2   
MAT,       1
REAL,       2   
ESYS,       0   
SECNUM,
TSHAP,LINE   
FLST,2,2,1
FITEM,2,2   
FITEM,2,3   
NWPAVE,       3
N,4,150,0,,,,,
N,5,229.18,127.4,,,,,   
TYPE,   1   
MAT,       1
REAL,       1   
ESYS,       0   
SECNUM,
TSHAP,ARC   
FLST,2,3,1
FITEM,2,3   
FITEM,2,5   
FITEM,2,4      
NWPAVE,       5
N,6,500,-310.77,,,,,
TYPE,   2   
MAT,       1
REAL,       2   
ESYS,       0   
SECNUM,
TSHAP,LINE   
FLST,2,2,1
FITEM,2,5   
FITEM,2,6   
NWPAVE,       6
N,7,-79.18,-127.4,,,,,
NWPAVE,       7
N,8,150,0,,,,,
TYPE,   1   
MAT,       1
REAL,       1   
ESYS,       0   
SECNUM,
TSHAP,ARC   
FLST,2,3,1
FITEM,2,6   
FITEM,2,8   
FITEM,2,7   
NWPAVE,       8
N,9,0,-12000,,,,,   
TYPE,   2   
MAT,       1
REAL,       2   
ESYS,       0   
SECNUM,
TSHAP,LINE   
FLST,2,2,1
FITEM,2,8   
FITEM,2,9   
NWPAVE,       9
N,10,150,0,,,,,
N,11,150,-150,,,,,
TYPE,   1   
MAT,       1
REAL,       1   
ESYS,       0   
SECNUM,
TSHAP,ARC   
FLST,2,3,1
FITEM,2,9   
FITEM,2,11
FITEM,2,10
NWPAVE,      11
N,12,1000,0,,,,,
TYPE,   2   
MAT,       1
REAL,       2   
ESYS,       0   
SECNUM,
TSHAP,LINE   
FLST,2,2,1
FITEM,2,11
FITEM,2,12
NWPAVE,      12
N,12,200,0,,,,,
TYPE,   2   
MAT,       1
REAL,       2   
ESYS,       0   
SECNUM,
TSHAP,LINE   
N,13,0,0,,,,,   
FLST,2,2,1
FITEM,2,13
FITEM,2,12
CSYS,0
WPAVE,0,0,0
SAVE
FINISH
/SOL
FLST,2,1,1,ORDE,1   
FITEM,2,13   
D,P51X, , , , , ,UX,UY,UZ,ROTX,ROTY,ROTZ
FLST,2,1,1,ORDE,1   
FITEM,2,2   
D,P51X, , , , , ,UX,UY,UZ,ROTX,ROTY,ROTZ
FLST,2,1,1,ORDE,1   
FITEM,2,2   
D,P51X, ,-7, , , ,UY, , , , ,
GPLOT   
/STATUS,SOLU
SOLVE   


tantgangbest001 发表于 2010-10-30 20:30

我想用pipe16和pipe60做管道的应力分析,但是用pipe60做弯管时,如果弯管的角度大于90°,就会有错误提示显示角度过大,但是我又不知道大于90°的角度要用哪个pipe元素,哪位高手指点下哈!
页: [1]