关于钢筋混凝土应力应变曲线的定义
!------------------------------------------------------!EX8.27 钢筋混凝土简支梁数值分析
!整体式模型,打开压碎,keyopt(1)=0,keyopt(7)=1
!力加载,位移收敛准则,误差1.5%,1/4模型分析
!--------------------------------------------
finish
/clear
/config,nres,2000
/prep7
!1.定义单元与材料性质--------------------
et,1,solid65,,,,,,,1
mp,ex,1,13585
mp,prxy,1,0.2
mp,ex,2,2.0e5
mp,prxy,2,0.3
fc=14.3
ft=1.43
tb,concr,1
tbdata,,0.5,0.95,ft,fc
tb,miso,1,,11
tbpt,,0.0002,fc*0.19
tbpt,,0.0004,fc*0.36
tbpt,,0.0006,fc*0.51
tbpt,,0.0008,fc*0.64
tbpt,,0.001,fc*0.75
tbpt,,0.0012,fc*0.84
tbpt,,0.0014,fc*0.91
tbpt,,0.0016,fc*0.96
tbpt,,0.0018,fc*0.99
tbpt,,0.002,fc
tbpt,,0.0033,fc*0.85
tb,biso,2
tbdata,,300,0
pi=acos(-1)
v1=0.25*pi*22*22*1.5/(75*60)
v2=0.25*pi*10*10/(75*60)
v3=0.25*pi*10*10*9.5/(1000*75)
v4=0.25*pi*10*10*9.5/(1000*60)
r,1,2,v1,0,90,2,v4
rmore,0,0,2,v3,90,0
r,2,2,v2,0,90,2,v4
rmore,0,0,2,v3,90,0
r,3,2,v3,90,0
上面这段命令流出自于《ANSYS工程结构数值分析》一书,目前有两个问题请教一下:
1.弹性模量值13585与规范中提供的30000不符?
2.“tbdata,,0.5,0.95,ft,fc”中0.5和0.95是纯系数还是具有量纲的数值,倘若希望把整个命令流修改为米制,这两个数字要不要放大?
敬请前辈们不吝赐教
本帖最后由 batista 于 2016-9-17 18:33 编辑
自己顶一下,继续研究……
我按照书上学的时候弹性模量也是13585不能按照规范做吧我也不清楚 Raspberry 发表于 2016-9-18 08:49
我按照书上学的时候弹性模量也是13585不能按照规范做吧我也不清楚
收到,谢谢 batista 发表于 2016-9-18 19:59
收到,谢谢
你解决了吗 Raspberry 发表于 2016-9-19 08:39
你解决了吗
还没,周末再好好研究下 是不是类似于模态分析啊给出的只是相对值 没有实际意义 sovereign 发表于 2016-9-20 08:42
是不是类似于模态分析啊给出的只是相对值 没有实际意义
还有待高手指点一下啊{:{05}:} batista 发表于 2016-9-20 22:42
还有待高手指点一下啊
我也只是猜测因为做模态分析的时候就是相对值 sovereign 发表于 2016-9-21 08:41
我也只是猜测因为做模态分析的时候就是相对值
好的 好的 谢了{:{05}:} 这个命令流怎么没算出结果来? Catsayer 发表于 2016-9-22 09:27
这个命令流怎么没算出结果来?
不是结果的问题,是命令流本身没看懂{:{27}:} 弄明白了吗? eastar 发表于 2016-9-23 09:01
弄明白了吗?
还没有,最近有点儿忙,等国庆后半程再好好试试,然后再跟大家汇报{:{05}:} 等待。。。。。。